Acoustical operating principle pressure gradient transducer
directional pattern cardioid
frequency range 20 hz ... 20 khz
sensitivity at 1 khz into 1 kohm 23 mv/pa = –32.5 dbv ± 1 db
rated impedance 50 ohms
rated load impedance 1 kohms
equivalent noise level, ccir 1 17.5 db
equivalent noise level, a-weighted 2 7 db-a
maximum spl for thd 0.5% 3 138 db
signal-to-noise ratio, ccir (re. 94 db spl) 4 76.5 db
signal-to-noise ratio, a-weighted (re. 94 db spl) 5 87 db
maximum output voltage 13 dbu
supply voltage (p48, iec 61938) 48 v ± 4 v
current consumption (p48, iec 61938) 3 ma
matching connector xlr 3 f
weight approx. 450 g
diameter 60 mm
length 132 mm